Beschrijving
Kenmerken
Geschikt voor ruimtes tot 400m2
Onderhoudsarm
Uitstekend bewezen betrouwbaarheid
5 jaar garantie
Ongeëvenaarde geluidskwaliteit
Uitstekende verstaanbaarheid
Automatische volumeregeling
Ruim dynamisch bereik voor een vervorming vrije hoge tonen weergaven
‘Metal loss’ correctie, corrigeert het frequentie afhankelijke verlies door Ferro metalen in constructies
Zeer compact: 215 x 220 x 44mm
Microfoon (XLR) en lijningangen
Diverse audio-aansluitmogelijkheden o.a. Jack & XLR
Toepassing
Vergader / conferentie ruimtes
Theaters
Sportzaal
Educatieve omgevingen
Gebedshuizen
Collegezalen
Specificaties
Inputs
Power
35 W 230 V AC nominal, 45-65 Hz Power switch and LED indicator on front panel
Microphone input
XLR balanced microphone input for 200-600 ? microphones;
15 dB user selectable gain boost; + 15 V DC phantom power (selectable); sensitivity – 70 dBu; front panel recessed gain control
Line input
6.4 mm jack socket balanced line input; sensitivity – 30 dBu; overload protected; front panel recessed gain control
Slave I/O
6.4 mm jack insert point for connection of SP5 phase shifter 0 dBu signal can be used for recording
Outputs
Drive voltage
6.4 Vrms (9.0V peak) at maximum output current
Drive current
• 4.9 Arms (7.0 Apk) continuous 1 kHz sine wave
• Short term peaks >10 Apk
• Front panel recessed control
• Drive current indicated on 4-LED display in 3 dB increments
Loop connector
Wieland ST17/2 (supplied)
Loop Monitor
Provides access to actual audio signal in loop via a 3.5 mm stereo headphone connector on front panel
Audio System
Freq. response
80 Hz to 6.5 kHz
Distortion
THD+N
Automatic Gain Control
The AGC is optimised for speech. Range >36 dBu Front panel recessed input level control
Metal loss correction
Corrects system frequency response due to metal structures in a building. Gain constant at 1 kHz, adjustable gain slope from 0 to 3 dB per octave
This does not compensate for signal loss from metal structures, which can be significant
Additional Functions
Fault Monitoring
Three LED fault indicators on the front panel:
• Overload – delivering over the rated current
• Overheat – unit is too hot (mutes output signal)
• Loop error – short circuit / open circuit error
Ancillary
To supply Ampetronic ancillary units ±15 V DC 0.15 A power outlet on rear panel
Cooling
Cooling is by natural convection from product casing
Physical
Dimensions
Half width 1U 19″ rack mount. Width 215 mm Depth 220 mm Height 44 mm
Weight
2,25kg
Environment
IP 20 protection; 20 to 90% relative humidity; 0 to 35 ºC
Mounting
Freestanding, wallmount, 1HE 19″ Rack (requires additional rack tray)